Lintel

CXL330 Cavity wall extreme load lintel

Product Applications
For 130mm Cavity, 100-115mm Inner Leaf

Product Benefits

  • Hot-dipped post galavanised
Standard Lengths (mm) SWL (kN) 5:1/19:1 Weight (kg/m) Nominal height 'h' (mm)
2100 - 3000 88 45.3 213
3300 - 4800 83 45.3 213
5100 78 45.3 213
5400 71 45.3 213
5700 64 45.3 213
6000 56 45.3 213
6300 52 45.3 213
6600 47 45.3 213
  • Standard lengths are available in 50mm increments for lengths up to 6600.
  • The SWL (safe working load) is based on the total UDL (uniform distributed load) over maximum span using 200mm end bearings.
  • A separate flexible DPC must be installed during construction.
  • As an optional extra, CXL lintels can be supplied with expanded metal mesh plaster key secured to the base plate.
  • To achieve the loading figures shown, the lintel must be laterally restrained and have 200mm end bearing supports and inner to outer load ratios between 5:1 and 19:33.